Order Code ORDER IN GTT ORDER SET Glucose Tolerance, 2 Hour, Plasma or Serum

Useful For

As an aid to diagnose diabetes mellitus

Specimen Requirements

Patient Preparation:

  1. Patient should eat a regular diet (at least 150 g of carbohydrates or 1,500 calories) for at least 3 days prior to testing.
  2. Advise patient to fast for at least 12 hours before test, and to avoid smoking or drinking coffee prior to and during test.
  3. When possible, this test should be administered in the morning, and patient should be advised to remain calm and quiet for duration of test.
  4. Vomiting negates the test

 

Blood glucose is drawn fasting, 1 hour and 2 hours after 75 g of oral bolus of glucose as follows:

  1. Following an overnight fast (8-14 hours), a fasting glucose is drawn, and processed immediately. Do NOT administer glucose beverage until fasting glucose is resulted. The glucose result must be < 200 mg/dL to proceed with the tolerance. If > 200 mg/dL, consult with physician (POC meter may be used for screening)
  2. After the fasting glucose results are evaluated, have the patient drink the 75 g glucose tolerance beverage.  Ingestion should be completed within 5 minutes.  The timing starts when the patient finishes the required dose of glucose tolerance beverage.
  3. Draw the additional specimens at 1 hour and 2 hours after the ingestion of the glucose tolerance beverage and label each specimen with correct collection time.

Note:  Contact Ridgeview Medical Center Laboratory at 952-442-2191 for special instructions on pediatric patients.

 

Specimen Type: Plasma or Serum

Collection Container/Tube:

Preferred: Green-top (lithium heparin) gel tube following an overnight (12-14 hours) fast.

Acceptable: Plain, red-top tube or SST

Specimen Volume: 2 mL

Pediatric (minimum) volume: 0.5 mL

Specimen Stability

Specimen Type Temperature Stability           
Plasma or Serum Ambient 24 hours
  Refrigerated (preferred) 7 days
  Frozen 6 months

Reference Values

2 hour GTT test (75 g glucose), adult

  • Fasting- normal: 70 - 100 mg/dl
  • Fasting- impaired: 101 - 125 mg/dl
  • Fasting- diabetes: > 126

1 hour specimen: No established ranges

 

2 hour specimen: 

  • Normal: 70 - 140 mg/dl
  • Impaired: 141 - 199 mg/dl
  • Confirmation of diabetes: > 200 mg/dl

A glucose tolerance test positive for diabetes should be confirmed by 1 additional fasting glucose of ≥126 mg/dL.

 

Critical values (automatic call-back)

  • Low: < 50 mg/dL
  • High: > 400 mg/dL

Day(s) Test Set Up

Monday through Sunday

Performing Laboratory

Ridgeview Medical Center Laboratory

Two Twelve Medical Center Laboratory

Ridgeview Sibley Medical Center Laboratory

Ridgeview Le Sueur Medical Center Laboratory

Methodology

Colorimetric

Test Classification and CPT Coding

82950