Order Code AACYL Aminoacylase-1 Deficiency, Urine
Necessary Information
1. Patient's age and sex are required.
2. Include family history, clinical condition (asymptomatic or acute episode), diet, and drug therapy information.
Specimen Required
Supplies: Urine Tubes, 10 mL (T068)
Container/Tube: Plastic, 10-mL urine tube
Specimen Volume: 10 mL
Pediatric: If insufficient collection volume, submit as much specimen as possible in a single container; the laboratory will determine if volume is sufficient for testing.
Collection Instructions:
1. Collect a random urine specimen (first morning void preferred).
2. No preservative.
Forms
Useful For
Follow-up quantitation of abnormal organic acid elevations of N-acetylated amino acids, in particular N-acetylalanine, N-acetylglycine, N-acetylmethionine, and N-acetylglutamic acid
Diagnosis of individuals with aminoacylase-1 deficiency
Evaluating patients with neurologic and psychiatric symptoms of unknown etiology
Special Instructions
Method Name
Gas Chromatography Mass Spectrometry (GC-MS)
Reporting Name
Aminoacylase-1 Deficiency, USpecimen Type
UrineSpecimen Minimum Volume
3 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Urine | Frozen (preferred) | 90 days |
Refrigerated | 60 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitabilityReference Values
N-acetylglycine: ≤15.00 mmol/mol creatinine
N-acetyl alanine: ≤10.00 mmol/mol creatinine
N-acetylglutamic acid: ≤20.00 mmol/mol creatinine
N-acetylmethionine: ≤5.00 mmol/mol creatinine
Method Description
Urine volumes equivalent to 0.25 to 0.50 mg of creatinine are spiked with the mixture of labeled internal standards, allowed to equilibrate, acidified, and then extracted. After evaporation, the dry residue is derivatized to butyl esters. Specimens are analyzed by capillary gas chromatography mass spectrometry selected ion monitoring using ammonia chemical ionization and a stable isotope dilution method.(Unpublished Mayo method)
Day(s) Performed
Monday
Performing Laboratory

CPT Code Information
82542