Order Code HAVTA Hepatitis A Virus Total Antibodies, Serum


Necessary Information


Date of collection is required.



Specimen Required


Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg. hair, skin, and nail supplements) containing biotin (vitamin B7).

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Serum gel (red-top tubes are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 0.6 mL

Collection Instructions:

1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).

2. Aliquot serum into plastic vial.


Useful For

Detection of recent or previous exposure or immunity to hepatitis A.

 

This test should not be used as a screening or confirmatory test for blood or solid or soft tissue donor specimens.

Special Instructions

Method Name

Electrochemiluminescence Immunoassay (ECLIA)

Reporting Name

Hepatitis A Virus Total Ab, S

Specimen Type

Serum SST

Specimen Minimum Volume

0.6 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum SST Frozen (preferred) 90 days
  Refrigerated  6 days
  Ambient  72 hours

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Reference Values

Unvaccinated: Negative

Vaccinated: Positive

Method Description

The Elecsys Anti-HAV (hepatitis A virus) II assay is performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. HAV-specific antibodies in the patient's serum binds with added HAV antigen in the reaction. After addition of biotinylated monoclonal anti-HAV and streptavidin-coated microparticles, patient's anti-HAV form a sandwich complex with the HAV antigen and the ruthenium-labeled anti-HAV antibody which becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode, and unbound substances are washed away. Voltage is applied to the electrode which induces chemiluminescent emissions that are measured by a photomultiplier. Test result is determined automatically with the assay-specific software in comparing the electrochemiluminescence signal generated in the patient's sample to the signal cutoff index value set from reagent lot-specific assay calibration.(Package insert: Elecsys Anti-HAV II. Roche Diagnostics; v3.0, 11/2022)

Day(s) Performed

Monday through Saturday

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

86708