Order Code LABPACPS Prostatic Acid Phosphatase, Serum
Additional Codes
| Mayo Test ID |
|---|
| PACP |
Reporting Name
Prostatic Acid Phosphatase, SUseful For
Aiding in predicting recurrence after radical prostatectomy for clinically localized prostate cancer
Following response to androgen ablation therapy, when used in conjunction with prostate-specific antigen
Specimen Type
SerumSpecimen Required
Patient Preparation: For 12 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.4 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 7 days |
| Frozen | 180 days |
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | OK |
Reference Values
≤2.1 ng/mL
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Day(s) Performed
Monday, Wednesday, Friday
Method Name
Automated Chemiluminescent Immunometric Assay
CPT Code Information
84066
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| PACP | Prostatic Acid Phosphatase, S | 20420-6 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| PACP | Prostatic Acid Phosphatase, S | 20420-6 |
Method Description
The patient sample is added to a solid phase that is coated with a mouse monoclonal antibody specific for prostatic acid phosphatase (PAP). A goat-anti-PAP-alkaline phosphatase conjugate is added to form an antibody sandwich complex. Excess conjugate is removed by washing, and an adamantyl dioxetane phosphate substrate is added to produce chemiluminescence. Light emission is proportional to PAP concentration in the specimen.(Package insert: IMMULITE 2000 PAP. PIL2KPA-17. Siemens Healthcare; 03/15/2018)