Sign in →

Order Code TRYPA Tryptase, Autopsy, Serum

Reporting Name

Tryptase, Autopsy

Useful For

Evaluation of autopsy cases in which anaphylaxis in the context of allergen exposure or mast cell activation is a suspected cause of death

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into plastic vial.

Additional Information: Tryptase degenerates very quickly when left in the presence of red blood cells.


Specimen Minimum Volume

0.2 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Frozen (preferred) 14 days
  Refrigerated  7 days

Reference Values

No established reference values

Day(s) Performed

Monday through Friday

CPT Code Information

83520

Method Description

Antitryptase, covalently coupled to ImmunoCAP, reacts with tryptase in the patient serum specimen. After washing, enzyme-labeled antibodies against tryptase are added to form a complex. After incubation, unbound enzyme-labeled antibodies are washed away, and the bound complex is incubated with a developing agent. After stopping the reaction, the fluorescence in the eluate is measured. The fluorescence is directly proportional to the concentration of tryptase in the serum specimen.(Package insert: ImmunoCAP Tryptase. Phadia AB; 10/2019)

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Method Name

Fluorescence Enzyme Immunoassay (FEIA)