Sign in →

Order Code BRFKT BRAF and KIT Mutation Analysis, Next-Generation Sequencing, Tumor


Necessary Information


A pathology report (final or preliminary), at minimum containing the following information, must accompany specimen for testing to be performed:

1. Patient name

2. Block number-must be on all blocks, slides, and paperwork (can be handwritten on the paperwork)

3. Tissue collection date

4. Source of the tissue



Specimen Required


This assay requires at least 20% tumor nuclei.

-Preferred amount of tumor area with sufficient percent tumor nuclei: tissue 216 mm(2)

-Minimum amount of tumor area: tissue 36 mm(2)

-These amounts are cumulative over up to 10 unstained slides and must have adequate percent tumor nuclei

-Tissue fixation: 10% neutral buffered formalin, not decalcified

-For specimen preparation guidance, see Tissue Requirement for Solid Tumor Next-Generation Sequencing. In this document, the sizes are given as 4 mm x 4 mm x 10 slides as preferred: approximate/equivalent to 144 mm(2) and the minimum as 3 mm x 1 mm x 10 slides: approximate/equivalent to 36 mm(2).

 

Preferred: Submit 3, if available, or 2 of the following specimens.

Acceptable: Submit at least one of the following specimens.

 

Specimen Type: Tissue block

Collection Instructions: Submit a formalin-fixed, paraffin-embedded tissue block with acceptable amount of tumor tissue.

 

Specimen Type: Tissue slide

Slides: 1 Hematoxylin and eosin-stained and 10 unstained

Collection Instructions:

Submit the following slides:

1 slide stained with hematoxylin and eosin

AND

10 unstained, nonbaked slides with 5-micron thick sections of the tumor tissue.

Note: The total amount of required tumor nuclei can be obtained by scraping up to 10 slides from the same block.

Additional Information: Unused unstained slides will not be returned.

 

Specimen Type: Cytology slide (direct smears or ThinPrep)

Slides: 1 to 3 Slides

Collection Instructions: Submit 1 to 3 slides stained and coverslipped with a total of 5000 nucleated cells (preferred), or a minimum of 3000 nucleated cells.

Note: Glass coverslips are preferred; plastic coverslips are acceptable but will result in longer turnaround times.

Additional Information: Cytology slides will not be returned. An image of the slides will be stored per regulatory requirements.


Useful For

Identifying specific mutations within the BRAF and KIT genes that predict response to therapy

Genetics Test Information

This test uses targeted next-generation sequencing to evaluate for somatic mutations within the BRAF and KIT genes. See Targeted Genes and Methodology Details for BRAF/KIT Mutation Analysis for details regarding the targeted gene regions evaluated by this test.

 

This test is performed to evaluate for somatic mutations within solid tumor samples. It does not assess for germline alterations within the BRAF and KIT genes.

Additional Tests

Test ID Reporting Name Available Separately Always Performed
SLIRV Slide Review in MG No Yes

Testing Algorithm

When this test is ordered, slide review will always be performed at an additional charge.

Method Name

Sequence Capture and Targeted Next-Generation Sequencing (NGS)

Reporting Name

BRAF/KIT Mutation Analysis, Tumor

Specimen Type

Varies

Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time
Varies Ambient (preferred)
  Refrigerated 

Reject Due To

All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Reference Values

An interpretive report will be provided.

Method Description

Next-generation sequencing is performed to evaluate the presence of a mutation in all coding regions of the BRAF and KIT genes. See Targeted Genes and Methodology Details for BRAF/KIT Mutation Analysis for details regarding the targeted gene regions evaluated by this test.(Unpublished Mayo method)

 

A pathology review and macro dissection to enrich for tumor cells are performed prior to slide scraping.

Day(s) Performed

Monday through Friday

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

88381-Microdissection, manual

81406

81479

81479 (if appropriate for government payers)

Forms

If not ordering electronically, complete, print, and send an Oncology Test Request (T729) with the specimen.