Sign in →

Order Code CDUOE Cadmium Occupational Exposure, Random, Urine


Specimen Required


Patient Preparation: High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.

Supplies: Urine Tubes, 10 mL (T068)

Collection Container/Tube: Clean, plastic urine container with no metal cap or glued insert

Submission Container/Tube: Plastic, 10-mL urine tube or clean, plastic aliquot container with no metal cap or glued insert

Specimen Volume: 3 mL

Collection Instructions:

1. Collect urine a random urine specimen.

2. See Metals Analysis Specimen Collection and Transport for complete instructions.


Useful For

Detecting occupational exposure to cadmium, a toxic heavy metal, using random urine specimens

Profile Information

Test ID Reporting Name Available Separately Always Performed
CDOU Cadmium Occupational Exposure No Yes
CRETR Creatinine, Random, U No Yes

Method Name

CDOU: Triple -Quadrupole Inductively Coupled Plasma  Mass Spectrometry (ICP-MS/MS)

CRETR: Enzymatic Colorimetric Assay

Reporting Name

Cadmium Occupat Exp, Random, U

Specimen Type

Urine

Specimen Minimum Volume

1.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 28 days
  Frozen  28 days
  Ambient  14 days

Reject Due To

  All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Reference Values

CADMIUM/CREATININE:

Biological Exposure Indices (BEI): <5.0 mcg/g creatinine

 

CREATININE:

≥18 years: 16-326 mg/dL

Reference values have not been established for patients who are younger than 18 years of age. 

Method Description

Cadmium:

The metal of interest is analyzed by triple-quadrupole inductively coupled plasma mass spectrometry.(Unpublished Mayo method)

 

Creatinine:

The enzymatic method is based on the determination of sarcosine from creatinine with the aid of creatininase, creatinase, and sarcosine oxidase. The liberated hydrogen peroxide is measured via a modified Trinder reaction using a colorimetric indicator. Optimization of the buffer system and the colorimetric indicator enables the creatinine concentration to be quantified both precisely and specifically.(Package insert: Creatinine plus ver 2. Roche Diagnostics; V15.0, 03/2019)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

82300

82570

Day(s) Performed

Monday through Friday