Sign in →

Order Code FHBG Hepatitis B Virus Genotyping

Reporting Name

Hepatitis B Virus Genotype

Performing Laboratory

ARUP Laboratories

Specimen Type

Plasma EDTA


Specimen Required


Specimen Type: Plasma

Collection Container/Tube: EDTA (lavender or pink top)

Submission Container/Tube: Plastic vial

Specimen Volume: 2 mL Plasma

Collection Instructions:

1.Centrifuge and aliquot 2 mL plasma into a plastic vial.

2. Send frozen.

 

Required:

1. Viral Load

2. Viral Load Date

 

Note: This test may be unsuccessful if the HBV Viral load is less than log 3.0 or 1000 IU/mL of plasma.


Specimen Minimum Volume

Plasma: 0.5 mL

Specimen Stability Information

Specimen Type Temperature Time
Plasma EDTA Frozen (preferred) 42 days
  Refrigerated  7 days
  Ambient  72 hours

Reference Values

Not detected

Day(s) Performed

Tuesday, Friday

CPT Code Information

87912

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FHBG Hepatitis B Virus Genotype 32366-7

 

Result ID Test Result Name Result LOINC Value
Z3195 Hepatitis B Genotype 32366-7
Z3196 HBV Surface Antigen Mutations 32366-7
Z3197 HBV RT Polymerase Mutations Unable to Verify

Reject Due To

Thawing: Cold OK; Warm OK
Heparinized specimens Reject

Method Name

Polymerase Chain Reaction/Sequencing