Sign in →

Order Code HBPES Hepatitis B Virus Past Exposure Panel, Serum


Necessary Information


Date of collection is required.



Specimen Required


Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Serum gel (red-top tubes are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 1.2 mL

Collection Instructions:

1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).

2. Aliquot serum into plastic vial.


Useful For

Screening for past exposure to hepatitis B virus (HBV)

 

Determining HBV infection and immunity status prior to initiating chemotherapy or other immunosuppressive agents

Profile Information

Test ID Reporting Name Available Separately Always Performed
HBGSN HBs Antigen Scrn, S Yes Yes
HBCSN HBc Total Ab Scrn, S Yes Yes
HBBSN HBs Antibody Scrn, S Yes Yes

Testing Algorithm

If hepatitis B surface antigen (HBsAg) is reactive, then HBsAg confirmation will be performed at an additional charge.

 

For more information see Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management

Method Name

Electrochemiluminescence Immunoassay (ECLIA)

Reporting Name

Hepatitis B Past Exposure, S

Specimen Type

Serum SST

Specimen Minimum Volume

0.9 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum SST Frozen (preferred) 90 days
  Refrigerated  6 days
  Ambient  7 hours

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Reference Values

Negative

See Viral Hepatitis Serologic Profiles.

Method Description

Hepatitis B Surface Antigen Screen:

The Elecsys HBsAg (hepatitis B surface antigen) II assay is based on the sandwich immunoassay principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. HBsAg present in the patient's sample reacts with two biotinylated monoclonal hepatitis B surface antibody (anti-HBs), and a mixture of monoclonal anti-HBs and polyclonal anti-HBs labeled with a ruthenium complex react to form a sandwich complex. After addition of streptavidin-coated microparticles (solid phase), the complexes bind to the solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Unbound substances are washed away, and voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Test result is determined by comparing the electrochemiluminescence signal generated from the reaction product in the patient's sample to the cutoff index (COI) value set from reagent lot-specific assay calibration.(Package insert: Elecsys HBsAG II. Roche Diagnostics; v3.0; 02/2022)

 

Hepatitis B Surface Antigen confirmation:

The Elecsys HBsAg II Auto Confirm assay is based on the sandwich immunoassay principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. This test is based on 2 parallel measurements. For the first measurement, the sample is treated with the control pretreatment reagent (PT2) prior to immunoreaction. This measurement serves as a reference. For the second measurement the sample is treated with the confirmatory pretreatment reagent (PT1) prior to immunoreaction. During incubation with confirmatory pretreatment, unlabeled polyclonal anti-HBs are bound to the sample HBsAg and thereby block the binding sites for the labeled antibodies used in the following immunoreaction. The confirmation result (%) is automatically assessed by determining the ratio of both measurements.

 

During testing, the auto-diluted sample is incubated with control pretreatment and confirmatory pretreatment, followed by formation of sandwich complexes of biotinylated monoclonal anti-HBs and a mixture of monoclonal anti-HBs and polyclonal anti-HBs labeled with a ruthenium complex. After addition of streptavidin-coated microparticles (solid phase), the complexes bind to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Unbound substances are then washed away, and voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Results are determined by comparing the electrochemiluminescence signal generated from the reaction product to the cutoff index value set from reagent lot-specific assay calibration. The confirmation result (%) is calculated from the ratio of the COI obtained for the measurement with confirmatory pretreatment to the COI obtained for the measurement of control pretreatment reaction.(Package insert: Elecsys HBsAg II Auto Confirm. Roche Diagnostics; v1.0, 12/2020)

 

Hepatitis B Surface Antibody:

Elecsys Anti-HBs (hepatitis B surface antibody) assay is based on the sandwich immunoassay principle and performed using an electrochemiluminescent immunoassay on the automated cobas e 801 immunochemistry analyzer. Anti-HBs present in patient's serum sample reacts with the biotinylated HBsAg (ad and ay subtypes) and HBsAg (ad/ay) labeled with a ruthenium complex to form a sandwich complex. After the addition of streptavidin-coated microparticles (solid phase), the complexes bind to the solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where microparticles are magnetically captured onto the surface of the electrode. Unbound substances are washed away, and voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. The emission signal generated is directly proportional to the concentration of anti-HBs present in the patient's serum sample. (Package insert: Elecsys Anti-HBs. Roche Diagnostics; v3.0, 03/2024)

 

Hepatitis B core Total Antibodies:

Elecsys Anti-HBc (hepatitis B core antibody) II assay is based on the competitive immunoassay principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. Patient's sample is pretreated first with a reducing reagent, and after the addition of hepatitis B virus core antigen (HBcAg), complexes are formed with HBc antibodies in the sample. The remaining unbound sites on the HBcAg become occupied with the added biotinylated antibodies and ruthenium complex-labeled antibodies specific for HBcAg. The entire complex binds to the streptavidin-coated microparticles (solid phase) via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. After unbound substances are washed away, voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Test result is determined by comparing the electrochemiluminescence signal generated from the reaction product in the sample to the cutoff index (COI) value set from assay reagent lot-specific assay calibration.(Package insert: Elecsys Anti-HBc II. Roche Diagnostics; v1.0, 04/2022)

Day(s) Performed

Monday through Saturday

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

86706

86704

87340

87341 (if appropriate)

G0499 (if appropriate)

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
HBGSC HBs Antigen Screen Confirmation, S No No