Order Code HEVQU Hepatitis E Virus RNA Detection and Quantification, Real-Time RT-PCR, Serum
Shipping Instructions
1. Freeze serum immediately, and ship specimen frozen on dry ice.
2. If shipment will be delayed for more 24 hours, freeze serum at -20 to -80° C (up to 35 days) until shipment on dry ice.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1.8 mL
Collection Instructions:
1. Centrifuge blood collection tube per collection tube manufacturer's instructions (eg, centrifuge within 2 hours of collection for BD Vacutainer tubes).
2. Aliquot serum into plastic vial.
Useful For
Virologic detection and confirmation of hepatitis E virus (HEV) infection in individuals who are immunocompromised and are at risk for or suspected to have acute or chronic hepatitis E
Monitoring HEV RNA levels and determining eradication of chronic HEV infection in individuals who are immunocompromised
Testing Algorithm
For more information see Hepatitis E: Testing Algorithm for Diagnosis and Management.
Special Instructions
Method Name
Real-Time Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR)
Reporting Name
HEV RNA Detect / Quant, SSpecimen Type
Serum SSTSpecimen Minimum Volume
0.8 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum SST | Frozen (preferred) | 35 days | ALIQUOT TUBE |
Refrigerated | 5 days | ALIQUOT TUBE |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Reference Values
Undetected
Method Description
This assay utilizes real-time polymerase chain reaction (PCR) technology for the qualitative and quantitative detection of hepatitis E virus (HEV) RNA in human serum. Testing involves 3 major processes with the ELITe InGenius integrated system: automated extraction and purification of viral RNA; reverse transcription of viral target RNA sequence to generate complementary DNA (cDNA); and PCR amplification of a 69-base pair sequence in the 5' end of the HEV open reading frame (ORF) 2 that encodes the viral capsid protein, followed by real-time detection of fluorescent dye-labeled oligonucleotide probes that allow the specific and simultaneous detection and quantification of the target sequence as well as an MS2 internal control. The assay is calibrated to the First World Health Organization International Standard for HEV RNA, PEI code 6329/10.(Germer JJ, Ankoudinova I, Belousov YS, et al. Hepatitis E virus detection and quantification by an RT-PCR assay calibrated to the World Health Organization Standard for HEV RNA. J Clin Microbiol. 2017;55[5]:1478-1487. doi:10.1128/JCM.02334-16)
Day(s) Performed
Varies
Performing Laboratory

CPT Code Information
87799
Forms
If not ordering electronically, complete, print, and send 1 of the following with the specimen:
-Gastroenterology and Hepatology Test Request (T728)
-Microbiology Test Request (T244)