Sign in →

Order Code HEXU Iohexol, Timed Collection, Urine

Reporting Name

Iohexol, U

Useful For

Determining glomerular filtration rate in urine specimens

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Urine


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Container/Tube: Plastic vial

Specimen Volume: 5 mL

Collection Instructions: Collect a timed urine specimen. Timing may be variable and patient dependent.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time
Urine Refrigerated (preferred) 7 days
  Frozen  35 days
  Ambient  7 days

Reference Values

Not applicable

Day(s) Performed

Monday through Friday

CPT Code Information

82542

LOINC Code Information

Test ID Test Order Name Order LOINC Value
HEXU Iohexol, U 93973-6

 

Result ID Test Result Name Result LOINC Value
61712 Iohexol, U 93973-6

Method Description

Timed urine specimens are obtained after subcutaneous injection of nonradiolabeled iohexol. Iohexol results are acquired via a liquid chromatography tandem mass spectrometry (LC-MS/MS) system. A ThermoFisher LX-2 Cohesive high-performance liquid chromatography system and an ABSciex 5500 MS/MS are used for analysis.(Seegmiller JC, Burns BE, Lieske JC, et al. Discordant glomerular filtration rate determinations between iothalamate and iohexol renal clearances. Poster presented at: Renal Week 2010. 43rd Annual Meeting of the American Society of Nephrology; November 16-21, 2010; Denver, CO)

Reject Due To

  All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Forms

If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.