Order Code HPLC High-Performance Liquid Chromatography (HPLC) Hemoglobin Variant, Blood


Specimen Required


Only orderable as part of a profile. For more information see:

-HAEV1 / Hemolytic Anemia Evaluation, Blood

-HBEL1 / Hemoglobin Electrophoresis Evaluation, Blood

-MEV1 / Methemoglobinemia Evaluation, Blood

-REVE2 / Erythrocytosis Evaluation, Blood

-THEV1 / Thalassemia and Hemoglobinopathy Evaluation, Blood and Serum


Useful For

Providing additional information, which aids in the identification of hemoglobin variants

Method Name

Only orderable as part of a profile. For more information see:

-HAEV1 / Hemolytic Anemia Evaluation, Blood

-HBEL1 / Hemoglobin Electrophoresis Evaluation, Blood

-MEV1 / Methemoglobinemia Evaluation, Blood

-REVE2 / Erythrocytosis Evaluation, Blood

-THEV1 / Thalassemia and Hemoglobinopathy Evaluation, Blood and Serum

 

Cation Exchange High-Performance Liquid Chromatography (HPLC)

Reporting Name

HPLC Hb Variant, B

Specimen Type

Whole Blood EDTA

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Whole Blood EDTA Refrigerated 10 days

Reject Due To

All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Reference Values

Only orderable as part of a profile. For more information see:

-HAEV1 / Hemolytic Anemia Evaluation, Blood

-HBEL1 / Hemoglobin Electrophoresis Evaluation, Blood

-MEV1 / Methemoglobinemia Evaluation, Blood

-REVE2 / Erythrocytosis Evaluation, Blood

-THEV1 / Thalassemia and Hemoglobinopathy Evaluation, Blood and Serum

Method Description

Hemolysate of whole blood is injected into an analysis stream passing through a cation exchange column using high-performance liquid chromatography. A pre-programmed gradient controls the elution buffer mixture that also passes through the analytical cartridge. The ionic strength of the elution buffer is raised by increasing the percentage of a second buffer. As the ionic strength of the buffer increases, the more strongly retained hemoglobins elute from the cartridge. Absorbance changes are detected by a dual-wavelength filter photometer. Changes in absorbance are displayed as a chromatogram of absorbance versus time.(Huismann TH, Schroeder WA, Brodie AN, et al. Microchromotography of hemoglobins. III. A simplified procedure for the determination of hemoglobin A2. J Lab Clin Med. 1975;86:700-702; Ou CN, Buffone GJ, Reimer GL, Alpert AJ. High-performance liquid chromatography of human hemoglobins on a new cation exchanger. J Chromatogr. 1983;266:197-205; instruction manual: Bio-Rad Variant II Beta-thalassemia Short Program Instructions for Use, L70203705. Bio-Rad Laboratories, Inc; 11/2011)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

83021

Day(s) Performed

Monday through Friday