Order Code HSMWB Hepatosplenomegaly Panel, Blood
Ordering Guidance
This test should not be used for monitoring patients with confirmed diagnoses. If the testing requested is for monitoring purposes, see:
-CTXWB / Cerebrotendinous Xanthomatosis, Blood
-GPSYW / Glucopsychosine, Blood
-OXYWB / Oxysterols, Blood
This test's clinical sensitivity and specificity for the identification of Niemann-Pick type C (NPC) is 75% and 89%, respectively. If NPC is strongly suspected, the recommended test is HSMP / Hepatosplenomegaly Panel, Plasma.
Specimen Required
Collection Container/Tube:
Preferred: Lavender top (EDTA)
Acceptable: Green top (sodium heparin, lithium heparin), yellow top (ACD B)
Specimen Volume: 1 mL
Collection Instructions: Send whole blood specimen in original vial. Do not aliquot.
Forms
If not ordering electronically, complete, print, and send a Biochemical Genetics Test Request (T798) with the specimen.
Useful For
As a component of the initial evaluation of a patient presenting with hepatosplenomegaly
This test is not useful for the identification of carriers.
This test should not be used as a monitoring for patients with confirmed diagnoses.
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Reporting Name
Hepatosplenomegaly Panel, BSpecimen Type
Whole bloodSpecimen Minimum Volume
0.25 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Whole blood | Refrigerated (preferred) | 72 hours | |
Ambient | 48 hours |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
CHOLESTANE-3-BETA,5-ALPHA,6-BETA-TRIOL
Cutoff: ≤0.800 nmol/mL
LYSO-SPHINGOMYELIN
Cutoff: ≤0.100 nmol/mL
GLUCOPSYCHOSINE
Cutoff: ≤0.040 nmol/mL
7-ALPHA-HYDROXY-4-CHOLESTEN-3-ONE (7aC4)
Cutoff: ≤0.750 nmol/mL
7-ALPHA,12-ALPAH-DIHYDROXYCHOLEST-4-en-3-ONE (12aC4)
Cutoff: ≤0.250 nmol/mL
GLOBOTRIAOSYLSPHINGOSINE
Cutoff: ≤0.034 nmol/mL
Method Description
Whole blood is spotted on filter paper and dried overnight. A 3-mm dried blood spot is extracted with internal standard. The extract is subjected to liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. The MS/MS is operated in the multiple reaction monitoring positive mode to follow the precursor to product species transitions for each analyte and internal standard. The ratio of the extracted peak areas to internal standard determined by the LC-MS/MS is used to calculate the concentration of in the sample.(Unpublished Mayo method)
Day(s) Performed
Tuesday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
82542