Order Code LAB1142 Blood Gas, Arterial Blood
Additional Codes
Test Name in EPIC | EPIC Test Code | Mnemomic |
RV ARTERIAL BLOOD GASES (LAB PERFORMED) | LAB1142 | ABGS |
RV ARTERIAL BLOOD GASES (POCT) | LAB1142 | ABGS |
Useful For
Evaluating and monitoring respiratory conditions
Specimen Requirements
Special Note: At RMC/TTMC, this specimen is collected by respiratory therapy only
Specimen Type: Arterial Whole Blood
Collection Container/Tube: Lithium Heparin syringe, NOT on ice
Specimen Volume: 1 mL
Specimen Stability
RMC/TTMC: Transport ASAP to laboratory, Maximum Stability: 30 minutes
RSMC/RLSH:Transport ambient specimen ASAP to laboratory, analyze specimen immediately
Reference Values
- pH: 7.35 - 7.45
- Critical value (automatic call-back): < 7.20 or > 7.60
- pCO2: 35 - 48 mm Hg
- Critical value (automatic call-back): > 60 mm Hg
- pO2: 83 - 108 mm Hg
- Critical value (automatic call-back): < 40 mm Hg
- O2 saturation: 94 - 98%
- HCO3: 21-28 mmol/L
- Base excess: (-2) - 3 mmol/L
Methodology
Includes pH, pCO2, pO2, O2 saturation, HCO3, and base excess.
Day(s) Test Set Up
Monday through Sunday
Performing Laboratory
Ridgeview Medical Center Laboratory
Ridgeview Medical Center CV Lab
Two Twelve Medical Center Laboratory
Ridgeview Sibley Medical Center Laboratory
Ridgeview Le Sueur Hospital Laboratory
Test Classification and CPT Coding
82805 when performed on the Werfen GEM series devices that provide a direct measurement of O2 saturation