Sign in →

Order Code LAB1781 Mercury, 24 Hour, Urine

Additional Codes

Mayo Test Code: HGU

Reporting Name

Mercury, 24 Hr, U

Useful For

Detecting mercury toxicity in 24-hour urine specimens

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Urine


Necessary Information


24-Hour volume (in milliliters) is required.



Specimen Required


Patient Preparation: High concentrations of gadolinium and iodine are known to potentially interfere with most inductively coupled plasma mass spectrometry-based metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.

Supplies: Urine Tubes, 10 mL (T068)

Collection Container/Tube: Clean, plastic urine container with no metal cap or glued insert

Submission Container/Tube: Plastic, 10-mL urine tube or a clean, plastic aliquot container with no metal cap or glued insert

Specimen Volume: 3 mL

Collection Instructions:

1. Collect urine for 24 hours.

2. Refrigerate specimen within 4 hours of completion of 24-hour collection.

3. See Metals Analysis Specimen Collection and Transport for complete instructions.

Additional Information: See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens for multiple collections.


Specimen Minimum Volume

1.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 7 days
  Frozen  7 days

Reference Values

0-17 years: Not established

≥18 years: <2 mcg/24 h

Toxic concentration: >50 mcg/24 h

The concentration at which toxicity is expressed is widely variable between patients. 50 mcg/24 h is the lowest concentration at which toxicity is usually apparent.

Day(s) Performed

Monday through Friday

CPT Code Information

83825

Method Description

The metal of interest is analyzed by triple-quadrupole inductively coupled plasma mass spectrometry.(Unpublished Mayo method)

Reject Due To

  All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Method Name

Triple-Quadrupole Inductively Coupled Plasma Mass Spectrometry (ICP-MS/MS)

Urine Preservative Collection Options

Note: The addition of preservative or application of temperature controls must occur within 4 hours of completion of the collection.

Ambient (no additive)

No

Refrigerate (no additive)

Preferred

Frozen (no additive)

OK

50% Acetic Acid

OK

Boric Acid

No

Diazolidinyl Urea

No

6M Hydrochloric Acid

OK

6M Nitric Acid

OK

Sodium Carbonate

No

Thymol

No

Toluene

No