Sign in →

Order Code LAB2009 Platelets, Blood

Additional Codes

Test Name in EPIC

EPIC Test Code           

Mnemonic

RV PLATELET COUNT

LAB2009

PLT

PRIOR TO 8/21/21: PLT

Useful For

Measuring platelet count in peripheral blood.  Platelets play a vital role in blood clotting. 

Specimen Requirements

Specimen Type: Whole Blood

Collection Container/Tube: Lavender (EDTA)

Pediatric Collection Container/Tube: Lavender Microtainer (EDTA)

Specimen Volume: optimal 2 mL, minimum 1 mL

Pediatric (microtainer) volume: 0.5 mL

 

Whole blood specimen should be inverted gently several times to mix blood immediately after collection. 

Specimen Stability

Specimen Type Temperature Stability         
Whole Blood Refrigerated 24 hours

Rejection Criteria

  1. Samples that do not meet minimum volume requirements
  2. Incorrect collection container
  3. Clotted or visibly hemolyzed

Reference Values

150 - 420 x 103/mm3

Day(s) Test Set Up

Monday through Sunday

Performing Laboratory

Ridgeview Medical Center Laboratory

Two Twelve Medical Center Laboratory

Ridgeview Sibley Medical Center Laboratory

Ridgeview Clinics

Methodology

Electronic Resistance Detection

Test Classification and CPT Coding

85049