Order Code LAB205 Luteinizing Hormone (LH), Serum
Additional Codes
Test Name in EPIC |
EPIC Test Code |
Mnemonic |
RV LUTEINIZING HORMONE |
LAB205 |
LH |
Useful For
Evaluation of menstrual irregularities, hypogonadism, ovulation, and pituitary disorders
Specimen Requirements
Specimen Type: Serum
Container/Tube:
Preferred: SST
Acceptable: Plain, red-top tube
Specimen Volume: 1.0 mL
Minimum Volume: 0.5 mL
Specimen Stability
Specimen Type | Temperature | Stability |
Serum | Ambient | 4 hours |
Refrigerated (preferred) | 5 days | |
Frozen | 4 weeks |
Reference Ranges
Male or Unspecified: No established Reference Range
Female: 2.58-12.1 mIU/mL
Phase |
Range (mIU/mL) |
Normal female follicular phase |
2.58–12.1 |
Normal female mid-cycle peak |
27.3–96.9 |
Normal female luteal phase |
0.833–15.5 |
Postmenopausal females |
13.1–86.5 |
Specimens with biotin concentrations up to 5ng/mL demonstrated a less than or equal to 10% change in results. Serum biotin concentrations >5 ng/mL may falsely decrease LH results.
For diagnostic purposes, the results should always be assessed in conjunction with the patient's medical history, clinical examination, and other findings.
Day(s) Test Set Up
Monday and Thursday
Performing Laboratory
Ridgeview Medical Center
Methodology
Immunometric immunoassay