Order Code LAB2061 Reticulocyte Count, Blood
Useful For
Assessing erythropoietic bone marrow activity in anemia and other hematologic conditions
Specimen Requirements
Specimen Type: Whole Blood
Collection Container/Tube: Lavender (EDTA)
Pediatric Collection Container/Tube: Lavender Microtainer (EDTA)
Specimen Volume: optimal 2 mL, minimum 1 mL
Pediatric (microtainer) volume: 0.5 mL
Whole blood specimen should be inverted gently several times to mix blood immediately after collection.
Specimen Stability
| Specimen Type | Temperature | Stability |
| Whole Blood | Refrigerated | 24 hours |
Rejection Criteria
- Samples that do not meet minimum volume requirements
- Incorrect collection container
- Clotted or visibly hemolyzed
Reference Values
STARTING MARCH 31, 2026
Gender abbreviations (M=Male, F=Female, U=Unknown, Unspecified, X=Neither Male nor Female)
|
Age/ gender |
Retic % |
Retic #X106/uL |
IRF % |
Retic Hgb pg |
|
0-4 Days |
3.47-5.40 |
0.1475-0.2164 |
30.5-35.1 |
27.6-38.7 |
|
4 days -1 mo |
1.06-2.37 |
0.0513-0.1104 |
14.5-24.6 |
27.6-38.7 |
|
1-2 mo |
2.12-3.47 |
0.0518-0.0779 |
19.1-28.9 |
27.6-38.7 |
|
2-6 mo |
1.55-2.70 |
0.0482-0.0882 |
13.4-23.3 |
27.6-38.7 |
|
6 mo-2 years |
0.99-1.82 |
0.0435-0.1111 |
11.4-25.8 |
* |
|
2-6 years |
0.82-1.45 |
0.0364-0.0680 |
8.4-21.7 |
* |
|
6-12 years |
0.98-1.94 |
0.0424-0.0702 |
8.9-24.1 |
* |
|
12-18 years |
0.90-1.49 |
0.0416-0.0651 |
9.0-18.7 |
* |
|
≥18 years |
0.60-2.71 |
0.0304-0.1109 |
2.3-13.5 |
* |
|
≥18 years |
0.60-2.71 |
0.0304-0.1109 |
2.3-15.5 |
* |
|
≥18 years |
0.60-2.71 |
0.0304-0.1109 |
2.3-15.5 |
* |
*only run on patients < 6 months old
Day(s) Test Set Up
Monday through Sunday
Performing Laboratory
Ridgeview Medical Center Laboratory
Methodology
Flow Cytometry Using Semiconductor Laser
Test Classification and CPT Coding
85045