Order Code LAB2061 Reticulocyte Count, Blood

Additional Codes

Test Name in EPIC

EPIC Test Code           

Mnemonic

RV RETICULOCYTE COUNT

LAB2061

RETIC

PRIOR TO 8/1/21:  RETIC

Useful For

Assessing erythropoietic bone marrow activity in anemia and other hematologic conditions

Specimen Requirements

Specimen Type: Whole Blood

Collection Container/Tube: Lavender (EDTA)

Pediatric Collection Container/Tube: Lavender Microtainer (EDTA)

Specimen Volume: optimal 2 mL, minimum 1 mL

Pediatric (microtainer) volume: 0.5 mL

 

Whole blood specimen should be inverted gently several times to mix blood immediately after collection. 

Specimen Stability

Specimen Type Temperature Stability         
Whole Blood Refrigerated 24 hours

Rejection Criteria

  1. Samples that do not meet minimum volume requirements
  2. Incorrect collection container
  3. Clotted or visibly hemolyzed

Day(s) Test Set Up

Monday through Sunday

Performing Laboratory

Ridgeview Medical Center Laboratory

Methodology

Flow Cytometry Using Semiconductor Laser

Test Classification and CPT Coding

85045