Order Code LAB26 Creatinine Clearance, Plasma or Serum and Urine -or- 24-Hour Creatinine Urine for Creatinine Clearance

Additional Codes

Test Name in EPIC

EPIC Test Code           

Mnemonic

RV CREATININE CLEARANCE

LAB26

UCRCL

 

Useful For

Estimation of glomerular filtration rate

Specimen Requirements

Urine and plasma or serum are required. Blood specimen should be drawn during 24-hour period of urine collection.

 

Urine

10 mL from a well-mixed, 24-hour urine collection. No preservative. Refrigerate specimen during collection.

  1. 24-Hour volume, time of collection, and patient’s height and weight are required.
  2. Follow instructions in Urine Collection in Special Instructions.

 

Blood

Specimen Type: Plasma or Serum

Preferred: Green-top (lithium heparin) gel tube.

Acceptable: Plain, red-top tube or SST

Specimen Volume: 2 mL

Pediatric (minimum) volume: 0.5 mL

Specimen Stability

Specimen Type Temperature Stability            
Urine/Plasma/Serum               Ambient 3 days
  Refrigerated (preferred) 5 days
  Frozen 6 months

Special Instructions

Day(s) Test Set Up

Monday through Sunday

Performing Laboratory

Ridgeview Medical Center Laboratory

Methodology

Two-point rate

Test Classification and CPT Coding

82570