Sign in →

Order Code LAB6218 Mitochondrial Antibodies (M2), Serum

Additional Codes

Mayo Test Code: AMA

Reporting Name

Mitochondrial Ab, M2, S

Useful For

Establishing the diagnosis of primary biliary cholangitis

 

This test is not useful for indicating the stage or prognosis of the disease or for monitoring the course of the disease.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Reference Values

Negative: <0.1 Units

Borderline: 0.1-0.3 Units

Weakly positive: 0.4-0.9 Units

Positive: ≥1.0 Units

Reference values apply to all ages.

Day(s) Performed

Monday through Saturday

CPT Code Information

86381

Method Description

A recombinant pyruvate dehydrogenase complex-E2 (M2) antigen for detection of antibodies against M2 is attached to the surface of a microplate. Diluted patient serum, standards, or controls are added to the wells, and the M2 specific IgG and IgM antibodies, if present, bind to the antigen. All unbound human antibodies are washed away, and a conjugate of enzyme-labeled polyclonal antibody to human IgG and IgM is added. The enzyme conjugate binds to the antibody complex. Excess enzyme-conjugate is washed away, and substrate is added. After a specified time, the enzyme reaction is stopped. The intensity of the color generated is proportional to the amount of anti-M2 IgG and/or IgM antibody in the sample. The results are read by a spectrophotometer producing a direct measurement of the anti-M2 IgG and IgM antibodies in the serum. Testing is performed on the Agility instrument by Dynex.(Package insert: Kallestad Anti-Mitochondrial Kit. Bio-Rad Laboratories, Inc; 10/2014)

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK
Heat-treated specimens Reject

Method Name

Enzyme Immunoassay (EIA)

Forms

If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:

-General Request (T239)

-Gastroenterology and Hepatology Test Request (T728)