Order Code LABCPOCX Carbapenem Resistant Organism Colonization Screening by Culture
Infectious
Useful For
This test detects KPC, NDM, VIM, IMP, OXA-23, OXA-24, OXA-48, and OXA-58 gene sequences associated with carbapenem-resistant organisms (CRO).CRO testing is used as an aid in infection control in the detection of CRO that colonize patients in health care settings and is not intended to guide or monitor treatment for CRO bacterial infections.
Specimen Requirements
Specimens:
Rectal source (Copan dual swab collection kit or equivalent), Wound or skin axilla and groin composite source (Eswab), Sputum, Stool.
Transport/Stability:
Store and ship at ambient (8°C to 25°C) or refrigerated (2°C to 8°C) temperature.
If Carbapenemase PCR, CarbaR - Specimen testing is also ordered on the same rectal swab, store and ship at ambient (8°C to 25°C) temperature within 5 days of collection.
Please see the MDH website for more info:
CRE Isolate Submission and Laboratory Testing - MN Dept. of Health
Performing Laboratory
Minnesota Department of Health Laboratory
Turn Around Time
3-7 Days
Methodology
Biochemicals, Conventional PCR, Culture, MALDI-TOF (matrix-assisted laser desorption ionization-time of flight) mass spectrometry, Real-time PCR
CPT