Order Code LABDULOX Duloxetine, Serum
Additional Codes
Mayo Test Code: DULOX
Reporting Name
Duloxetine, SUseful For
Monitoring duloxetine serum concentration during therapy
Evaluating potential duloxetine toxicity
Evaluating patient compliance
Performing Laboratory

Specimen Type
Serum RedSpecimen Required
Collection Container/Tube: Red top (serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Draw blood immediately before the next scheduled dose (trough).
2. Centrifuge and aliquot serum into plastic vial within 2 hours of collection.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum Red | Refrigerated (preferred) | 28 days |
Ambient | 28 days | |
Frozen | 28 days |
Reference Values
30-120 ng/mLDay(s) Performed
Wednesday
CPT Code Information
80299
Method Description
Serum samples containing duloxetine are diluted in an aqueous solution containing deuterated internal standard and then injected onto a high-turbulence liquid chromatography system for online extraction. Detection is by tandem mass spectrometry.(Unpublished Mayo method)
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Forms