Order Code LABGOR, CRU Chromium, 24 Hour, Urine
Additional Codes
Mayo Test Code: CRU
Reporting Name
Chromium, 24 Hr, UUseful For
Screening for occupational exposure to chromium
Monitoring metallic prosthetic implant wear
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
UrineOrdering Guidance
High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Specimen Required
Supplies: Urine Tubes, 10 mL (T068)
Collection Container/Tube: Clean, plastic urine container with no metal cap or glued insert
Submission Container/Tube: Plastic, 10-mL urine tube or clean, plastic aliquot container with no metal cap or glued insert
Specimen Volume: 0.5 mL
Collection Instructions:
1. Collect urine for 24 hours.
2. Refrigerate specimen within 4 hours of completion of 24-hour collection.
3. See Metals Analysis Specimen Collection and Transport for complete instructions.
Additional Information:
1. 24-Hour volume is required.
2. See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens for multiple collections.
Specimen Minimum Volume
0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Special Instructions
Reference Values
0-17 years: Not established
≥18 years: 0.1-1.2 mcg/24 hours
Day(s) Performed
Tuesday, Wednesday, Friday
CPT Code Information
82495
Method Description
The metal of interest is analyzed by inductively coupled plasma mass spectrometry.(Unpublished Mayo method)
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability. |
Method Name
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)