Order Code LABHCMCMISC, O66666 Heparin Neutralization Panel (HCMC)
Additional Codes
Order Misc HCMC EPIC Test: LABHCMCMISC
HCMC Test Code: O66666
Specimen Requirements
Light Blue (Sodium Citrate 3.2%)
Note: Tube must be > 90% full to ensure proper 1:9 ratio of anticoagulant.
Note: For coagulation tests only. Please send the original collection container to the main lab at HCMC along with any aliqout or pour over.
Order as a Miscellaneous HCMC Test Code [ LABHCMCMISC ]. Add test name O66666
Fill out HCMC lab requisition form. Keep yellow copy and file at front desk.
Call RMC Courrier to deliver specimen.
Specimen Stability
Specimen must be centrifuged and plasma separated from red blood cells within 1 hour of collection.
After separation from cells:
Ambient: 4 hours
Refrigerated: 4 hours
Frozen: 2 weeks at -20°C
Reference Values
HCMC Ranges:
Test | Reference Range | Critical Value |
---|---|---|
Protime and INR - Hepzyme |
No Anticoagulation Thereapy: PT: 9.0 – 12.5 seconds INR: 0.8 – 1.2 |
INR ≥ 5.0 |
aPTT - Hepzyme | 25.0 - 37.0 seconds | >100 seconds |
Thrombin Time - Hepzyme | 13 - 17 seconds | Not Applicable |
Fibrinogen - Hepzyme | 200-400 mg/dL | <100 mg/dL |
Performing Laboratory
HCMC Clinical Laboratory
TAT: Within 24 Hours: 60 minutes once received by HCMC Clinical Laboratory
Lab results will be scanned in to EPIC Beaker
Performed: 24 Hours, 7 Days/Week