Order Code LABRPRREV Rapid Plasma Reagin (RPR) with Reflex to RPR Titer or T. pallidum Antibody by Particle Agglutination
Additional Codes
ARUP Test Code:2007443
Treponema Total Antibody Test: LABRPRREV
Useful For
Reflex from LABTRPAB to confirm a reactive or equivocal treponemal screening test (eg, CIA, EIA) when using the reverse testing algorithm to screen for syphilis.
Specimen Requirements
Collect: Serum separator tube (SST).
Specimen Preparation: Separate serum from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP standard transport tube. (Min: 0.5 mL). Avoid freezing if possible.
Storage/Transport Temperature: Refrigerated.
Specimen Stability
After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles)
Rejection Criteria
Unacceptable Conditions: Plasma, CSF, or other body fluids.
Reference Values
Rapid Plasma Reagin (RPR): Nonreactive
Treponema pallidum Antibody by TP-PA: Nonreactive
NOTE: if RPR is reactive, then a titer to endpoint will be added. If RPR is nonreactive, a TP-PA (MHA) confirmation will be added. Additional charges apply.
Day(s) Test Set Up
RPR: Sunday - Satuday
TP-PA: Monday - Friday
Performing Laboratory
ARUP Laboratories
Methodology
RPR: Semi-Quantitative Particle Agglutination
TP-PA: Qualitative Particle Agglutination
Test Classification and CPT Coding
86592 RPR; if reflexed, add (nonreactive) TP-PA 86780 or (reactive) 86593 RPR titer