Order Code LABRVPC Respiratory Pathogen Panel, Molecular Detection (NICU Use Only)
Additional Codes
| Test Name in EPIC | EPIC Test Code | Mnemonic |
|---|---|---|
| RV RESPIRATORY PATHOGEN PANEL, MOLECULAR DETECTION | LABRVPC | RVPC |
| NICU RESPIRATORY PATHOGEN PANEL | O428586 | N/A |
Useful For
Rapid detection of respiratory infections caused by the following:
-Adenovirus
-Coronavirus serotypes HKU1, NL63, 229E, OC43
-SARS-CoV-2, the causative agent of COVID-19
-Human metapneumovirus
-Human rhinovirus/enterovirus
-Influenza A subtypes H1, H1-2009, H3, influenza A undifferentiated subtypes (including subtype H5N1)
-Influenza B
-Parainfluenza virus serotypes 1-4
-Respiratory syncytial virus (RSV)
-Bordetella pertussis
-Bordetella parapertussis
-Chlamydia pneumoniae
-Mycoplasma pneumoniae
Specimen Requirements
Supplies: Nasopharyngeal Swab (Rayon Mini-Tip Swab) (T515)
Container/Tube: Universal transport media, viral transport media (eg, Copan UTM-RT, BD VTM, MicroTest M4, M4-RT, M5).
Specimen Volume: Entire 3 mL collection
Collection Instructions:
1. Collect specimen by swabbing back and forth over nasal or pharyngeal mucosa surface to maximize recovery of cells.
2. Swab must be placed into transport medium. Swab shaft should be broken so that the there is no obstruction to the sample or pressure on the media container cap.
3. Do not send in glass tube.
Specimen Stability
| Specimen Type | Temperature | Stability |
| Nasopharyngeal Swab | Ambient (15-25⁰C) | 4 hours |
| Refrigerated (2-8⁰C) | 3 days | |
| Frozen (≤ -15⁰C) | 30 days |
Reference Values
Not Detected (for all targets)
Day(s) Test Set Up
Monday - Sunday
Performing Laboratory
Ridgeview Medical Center Laboratory
Methodology
PCR
Test Classification and CPT Coding
0202U
Rejection Criteria
- Specimen type other than a Nasopharyngeal (NP) swab
- Glass tubes