Order Code MACNT Macadamia Nut, IgE, Serum
Ordering Guidance
For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL for every 5 allergens requested
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Useful For
Establishing the diagnosis of an allergy to macadamia nut
Defining the allergen responsible for eliciting signs and symptoms
Identifying allergens:
-Responsible for allergic response and/or anaphylactic episode
-To confirm sensitization prior to beginning immunotherapy
-To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens
Testing for IgE antibodies is not useful in patients previously treated with immunotherapy to determine if residual clinical sensitivity exists, or in patients in whom the medical management does not depend upon identification of allergen specificity.
Special Instructions
Method Name
Fluorescence Enzyme Immunoassay (FEIA)
Reporting Name
Macadamia Nut, IgESpecimen Type
SerumSpecimen Minimum Volume
For 1 allergen: 0.3 mL
More than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL dead space
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 90 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Reference Values
Class |
IgE kU/L |
Interpretation |
0 |
<0.10 |
Negative |
0/1 |
0.10-0.34 |
Borderline/equivocal |
1 |
0.35-0.69 |
Equivocal |
2 |
0.70-3.49 |
Positive |
3 |
3.50-17.4 |
Positive |
4 |
17.5-49.9 |
Strongly positive |
5 |
50.0-99.9 |
Strongly positive |
6 |
≥100 |
Strongly positive |
Reference values apply to all ages.
Method Description
Specific IgE from the patient's serum reacts with the allergen of interest, which is covalently coupled to an ImmunoCAP. After washing away nonspecific IgE, enzyme-labeled anti-IgE antibody is added to form a complex. After incubation, unbound anti-IgE is washed away, and the bound complex incubated with a developing agent. After stopping the reaction, the fluorescence of the eluate is measured. Fluorescence is proportional to the amount of specific IgE present in the patient's sample (ie, the higher the fluorescence value, the more IgE antibody is present).(Package insert: ImmunoCAP System Specific IgE FEIA. Phadia; Rev 06/2020)
Day(s) Performed
Monday through Friday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
86003
Forms
If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.