Order Code MPNML MPL Exon 10 Sequencing, Reflex, Varies
Specimen Required
Only orderable as a reflex. For more information see MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies.
Useful For
Aiding in the distinction between a reactive cytosis and a myeloproliferative neoplasm when JAK2 V617F testing result is negative
Evaluates for variants in MPL in an algorithmic process for MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies
Method Name
Only orderable as a reflex. For more information see MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies.
Sanger Sequencing
Reporting Name
MPL Exon 10 Sequencing, ReflexSpecimen Type
VariesSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Varies |
Reject Due To
Gross hemolysis | Reject |
Paraffin-embedded bone marrow aspirate clot or biopsy blocks Slides Paraffin shavings Moderately to severely clotted |
Reject |
Reference Values
Only orderable as a reflex. For more information see MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies.
An interpretive report will be provided.
Method Description
Genomic DNA is extracted, and Sanger sequencing is used to evaluate for alterations in MPL, exon 10. The sensitivity of this assay is approximately 20%, such that samples containing lower percentages of altered DNA will appear negative.(Unpublished Mayo method)
Day(s) Performed
Monday through Friday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
81339-MPL (myeloproliferative leukemia virus oncogene, thrombopoietin receptor, TPOR) (eg, myeloproliferative disorder), exon 10 sequence