Order Code MRDMR Multiple Myeloma Minimal Residual Disease by Flow Cytometry, Bone Marrow
Specimen Required
Only orderable as a reflex. For more information see MSMRD / Myeloma Stratification and Risk-Adapted Therapy with Reflex to Minimal Residual Disease, Bone Marrow
Specimen Type: Redirected bone marrow
Container/Tube:
Preferred: Yellow top (ACD solution A or B)
Acceptable: Lavender top (EDTA)
Specimen Volume: 4 mL
Useful For
Detecting low level (minimal residual disease) myeloma cells after therapy to confirm remission has been achieved
Method Name
Only orderable as a reflex. For more information see MSMRD / Myeloma Stratification and Risk-Adapted Therapy with Reflex to Minimal Residual Disease, Bone Marrow
Immunophenotyping
Reporting Name
Multiple Myeloma MRD by Flow, BMSpecimen Type
Bone MarrowSpecimen Minimum Volume
2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Bone Marrow | Ambient (preferred) | 72 hours | |
Refrigerated | 72 hours |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
Only orderable as a reflex. For more information see MSMRD / Myeloma Stratification and Risk-Adapted Therapy with Reflex to Minimal Residual Disease, Bone Marrow
An interpretive report will be provided.
Method Description
Flow cytometric immunophenotyping for minimal residual disease (MRD) of bone marrow is performed using the following antibodies:
Tube 1: CD138, CD27, CD38, CD56, CD45, CD19, CD117, and CD81.
Tube 2: CD138, CD27, CD38, CD56, CD45, CD19, cyKappa, and cyLambda.
Abnormal plasma cell populations are detected through demonstrating CD38 (multi-epitope) and CD138 positivity along with immunoglobulin light chain restriction (ie, the presence of either predominately kappa or lambda immunoglobulin light chains) and abnormality of CD56, CD117, CD27, CD81, CD19 and/or CD45 expression.
The sensitivity of this assay is conservatively estimated to be 0.001% (1 x 10[-5]) with a minimum number of 2 x 10(-6) total events collected, and an abnormal plasma cell immunophenotype detected in a cluster of at least 20 cells and can be as high as 0.0002% (2 x 10[-6]). The sensitivity of the assay will be lower in samples with less than 2 x 10(-6) total events acquired. The validated limit of detection (sensitivity) meets the current National Comprehensive Cancer Network, International Myeloma Working Group, and EuroFlow guidelines for MRD assessment by flow cytometry in multiple myeloma. The percentage of clonal plasma cells estimated by flow cytometry is affected by specimen processing and antigen loss with specimen aging. MRD reporting is affected by sample volume and cellularity.(Unpublished Mayo method)
Day(s) Performed
Preanalytical processing: Monday through Saturday
Results reported: Monday through Friday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
88184-Flow Cytometry; first cell surface, cytoplasmic or nuclear marker
88185 x 9-Flow Cytometry; additional cell surface, cytoplasmic or nuclear marker
88188-Flow Cytometry Interpretation, 9 to 15 Markers