Sign in →

Order Code PAS8 Pediatric Allergy Screen >8 Years, Serum

Reporting Name

Pediatric Allergy Scrn >8 Yrs, S

Useful For

Establishing a diagnosis of an allergy to pediatric allergy screen

 

Defining the allergen responsible for eliciting signs and symptoms

 

Identifying allergens:

-Responsible for allergic response and/or anaphylactic episode

-To confirm sensitization prior to beginning immunotherapy

-To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens

Profile Information

Test ID Reporting Name Available Separately Always Performed
DF House Dust Mites/D.F., IgE Yes Yes
SRW Short Ragweed, IgE Yes Yes
TIMG Timothy Grass, IgE Yes Yes
CAT Cat Epithelium, IgE Yes Yes
ALTN Alternaria Tenuis, IgE Yes Yes

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Ordering Guidance


For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies



Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.7 mL for every 5 allergens requested

Collection Instructions: Centrifuge and aliquot serum into a plastic vial. 


Specimen Minimum Volume

For 1 allergen: 0.5 mL
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL deadspace

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  90 days

Reference Values

Class

IgE kU/L

Interpretation

0

<0.10

Negative

0/1

0.10-0.34

Borderline/equivocal

1

0.35-0.69

Equivocal

2

0.70-3.49

Positive

3

3.50-17.4

Positive

4

17.5-49.9

Strongly positive

5

50.0-99.9

Strongly positive

6

≥100

Strongly positive

Reference values apply to all ages.

Day(s) Performed

Monday through Friday

CPT Code Information

86003 x 5

Method Description

Specific IgE from the patient's serum reacts with the allergen of interest, which is covalently coupled to an ImmunoCAP. After washing away nonspecific IgE, enzyme-labeled anti-IgE antibody is added to form a complex. After incubation, unbound anti-IgE is washed away, and the bound complex incubated with a developing agent. After stopping the reaction, the fluorescence of the eluate is measured. Fluorescence is proportional to the amount of specific IgE present in the patient's sample (ie, the higher the fluorescence value, the more IgE antibody is present).(Package insert: ImmunoCAP System Specific IgE FEIA. Phadia; Rev 06/2020)

Reject Due To

Gross hemolysis OK
Gross lipemia OK

Method Name

Fluorescence Enzyme Immunoassay (FEIA)

Forms

If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.