Order Code PLA2M Phospholipase A2 Receptor, Monitoring, Enzyme-Linked Immunosorbent Assay, Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into plastic vial
Useful For
Distinguishing primary from secondary membranous nephropathy
Monitoring patients with membranous nephropathy, over time, for trends in anti-phospholipase A2 receptor antibody levels
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Reporting Name
PLA2R, Monitoring, ELISA, SSpecimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum | Refrigerated (preferred) | 14 days |
Frozen | 14 days | |
Ambient | 8 hours |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
<14 RU/mL: Negative
14 to 19 RU/mL: Borderline
≥20 RU/mL: Positive
Method Description
The test kit provides microtiter strips, each with 8 break-off reagent wells. In the case of positive samples, specific IgG antibodies (also IgA and IgM) will bind to the antigens. To detect the bound antibodies, a second incubation is carried out using an enzyme-labelled antihuman IgG (enzyme conjugate) catalyzing a color reaction.(Package insert: Anti-PLA2R ELISA [IgG] Kit. EUROIMMUN US; V 07/2020)
Day(s) Performed
Monday through Friday
Performing Laboratory

CPT Code Information
83520
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.