Order Code RT3 T3 (Triiodothyronine), Reverse, Serum
Additional Codes
Mayo Test ID |
---|
RT3 |
Reporting Name
T3 (Triiodothyronine), Reverse, SUseful For
Aiding in the diagnosis of the sick euthyroid syndrome
Specimen Type
SerumSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 0.8 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
10-24 ng/dL
Performing Laboratory
Mayo Clinic Laboratories in RochesterDay(s) Performed
Monday through Friday
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Portions of this test are covered by patents held by Quest Diagnostics.
CPT Code Information
84482
Method Description
Reverse T3-carbon 13 is added to serum samples as an internal standard. Reverse T3 (RT3) and RT3-carbon 13 are dissociated with a protein precipitation and then extracted from the specimens using a solid phase extraction. The eluate is dried down under nitrogen, reconstituted with mobile phase and analyzed by liquid chromatography tandem mass spectrometry using multiple reaction monitoring in the positive mode.(Unpublished Mayo Method)