Sign in →

Order Code RT3 T3 (Triiodothyronine), Reverse, Serum

Additional Codes

Mayo Test ID
RT3

Reporting Name

T3 (Triiodothyronine), Reverse, S

Useful For

Aiding in the diagnosis of the sick euthyroid syndrome

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 0.8 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
  Ambient  28 days
  Frozen  28 days

Reject Due To

Gross hemolysis Reject
Gross lipemia OK
Gross icterus OK

Reference Values

10-24 ng/dL

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Day(s) Performed

Monday through Friday

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Portions of this test are covered by patents held by Quest Diagnostics.

CPT Code Information

84482

Method Description

Reverse T3-carbon 13 is added to serum samples as an internal standard. Reverse T3 (RT3) and RT3-carbon 13 are dissociated with a protein precipitation and then extracted from the specimens using a solid phase extraction. The eluate is dried down under nitrogen, reconstituted with mobile phase and analyzed by liquid chromatography tandem mass spectrometry using multiple reaction monitoring in the positive mode.(Unpublished Mayo Method)

Forms

If not ordering electronically, complete, print, and send a General Request (T239) with the specimen.