Order Code SFIGS IgG, Serum
Specimen Required
Only orderable as part of a profile. For more information see SFIG / Cerebrospinal Fluid (CSF) IgG Index Profile, Serum and Spinal Fluid.
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial within 2 hours of collection.
Useful For
Aiding in the diagnosis of multiple sclerosis and other CNS inflammatory conditions
Method Name
Only orderable as part of a profile. For more information see SFIG / Cerebrospinal Fluid (CSF) IgG Index Profile, Serum and Spinal Fluid.
Nephelometry
Reporting Name
IgG, SSpecimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | |
Frozen | 28 days | ||
Ambient | 14 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | Reject |
Gross icterus | OK |
Reference Values
Only orderable as part of a profile. For more information see SFIG / Cerebrospinal Fluid (CSF) IgG Index Profile, Serum and Spinal Fluid.
0-4 months: 100-334 mg/dL
5-8 months: 164-588 mg/dL
9-14 months: 246-904 mg/dL
15-23 months: 313-1,170 mg/dL
2-3 years: 295-1,156 mg/dL
4-6 years: 386-1,470 mg/dL
7-9 years: 462-1,682 mg/dL
10-12 years: 503-1,719 mg/dL
13-15 years: 509-1,580 mg/dL
16-17 years: 487-1,327 mg/dL
≥18 years: 767-1,590 mg/dL
Method Description
The test is performed by nephelometry. The light scattered onto the antigen-antibody complexes is measured. The intensity of the measured scattered light is proportional to the amount of antigen-antibody complexes in the sample under certain conditions. If the antibody volume is kept constant, the signal behaves proportionally to the antigen volume.
A reference curve is generated by a standard with a known antigen content on which the scattered light signals of the samples can be evaluated and calculated as an antigen concentration. Antigen-antibody complexes are formed when a sample containing antigen and the corresponding antiserum are put into a cuvette. A light beam is generated with a light emitting diode (LED), which is transmitted through the cuvette. The light is scattered onto the immuno-complexes that are present. Antigen and antibody are mixed in the initial measurement, but no complex is formed yet. An antigen-antibody complex is formed in the final measurement.
The result is calculated by subtracting value of the final measurement from the initial measurement. The distribution of intensity of the scattered light depends on the ratio of the particle size of the antigen-antibody complexes to the radiated wavelength.(Instruction manual: Siemens Nephelometer II Operations. Siemens, Inc; V 2.3, 2008; Addendum to the Instruction Manual 2.3, 08/2017)
Day(s) Performed
Monday through Friday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
82784