Order Code SLA Soluble Liver Antigen (SLA) IgG Antibodies, Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL Serum
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Forms
If not ordering electronically, complete, print, and send Gastroenterology and Hepatology Test Request (T728) with the specimen.
Useful For
Evaluation of patients at-risk for autoimmune hepatitis or liver disease of unknown etiology
Testing Algorithm
For information see First-Line Screening for Autoimmune Liver Disease Algorithm.
Special Instructions
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Reporting Name
Soluble Liver Antigen Ab, IgG, SSpecimen Type
SerumSpecimen Minimum Volume
Serum: 0.4 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 21 days |
| Frozen | 21 days |
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | Reject |
| Gross icterus | OK |
| Heat treated specimens | Reject |
Reference Values
Negative: <20.0 U
Equivocal: 20.0-24.9 U
Positive: ≥ 25.0 U
Method Description
Partially purified, full-length recombinant human soluble liver antigen (SLA) is bound to the wells of a polystyrene microwell plate under conditions that will preserve the antigen in its native state. Prediluted controls and diluted patient sera are added to separate wells, allowing any SLA antibodies present to bind to the immobilized antigen. Unbound sample is washed away and an enzyme labeled anti-human IgG conjugate is added to each well. A second incubation allows the enzyme labeled anti-human IgG to bind to any patient antibodies that have become attached to the microwells. After washing away any unbound enzyme labeled anti-human IgG, the remaining enzyme activity is measured by adding a chromogenic substrate and measuring the intensity of the color that develops. The assay can be evaluated spectrophotometrically by measuring and comparing the color intensity that develops in the patient wells with the color in the control wells.(Package insert: QUANTA Lite SLA ELISA 708775. INOVA Diagnostics; Rev. 6, 11/2021)
Day(s) Performed
Monday
Performing Laboratory
Mayo Clinic Laboratories in Rochester
CPT Code Information
83516
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| SLA | Soluble Liver Antigen Ab, IgG, S | 32219-8 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| SLA | Soluble Liver Antigen Ab, IgG, S | 32219-8 |