Order Code THCCR Delta 9-Carboxy-Tetrahydrocannabinol (THC-COOH) Confirmation and Creatinine Ratio, Random, Urine
Specimen Required
Supplies: Urine Tubes, 10 mL (T068)
Collection Container/Tube: Plastic urine container
Submission Container/Tube: 10-mL tube
Specimen Volume: 10 mL
Collection Instructions:
1. Collect a random urine specimen.
2. Submit 10 mL in a plastic container.
3. No preservative.
Additional Information:
1. No specimen substitutions.
2. Submitting less than 10 mL may compromise the ability to perform all necessary testing.
3. STAT requests are not accepted for this test.
Useful For
Measuring the delta-9 carboxy-tetrahydrocannabinol to creatinine ratio to detect use of tetrahydrocannabinol
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
THCCU | THC-COOH/Creatinine Ratio, U | No | Yes |
CRETR | Creatinine, Random, U | No | Yes |
Method Name
THCCU: Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
CRETR: Enzymatic Colorimetric Assay
Reporting Name
THC-COOH/Creatinine Ratio, USpecimen Type
UrineSpecimen Minimum Volume
6 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 14 days | |
Frozen | 14 days | ||
Ambient | 72 hours |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
Carboxy-Tetrahydrocannabinol (THC):
Not Detected
Cutoff concentration:
Delta-9 Carboxy-tetrahydrocannabinol by liquid chromatography tandem mass spectrometry: <5.0 ng/mL
Creatinine:
≥18 years old: 16-326 mg/dL
Reference values have not been established for patients who are younger than 18 years.
Method Description
Delta-9 Carboxy-Tetrahydrocannabinol:
Confirmation with quantification by liquid chromatography tandem mass spectrometry.(Unpublished Mayo method)
Creatinine:
The enzymatic method is based on the determination of sarcosine from creatinine with the aid of creatininase, creatinase, and sarcosine oxidase. The liberated hydrogen peroxide is measured via a modified Trinder reaction using a colorimetric indicator. Optimization of the buffer system and the colorimetric indicator enables the creatinine concentration to be quantified both precisely and specifically.(Package insert: Creatinine plus ver 2. Roche Diagnostics; V15.0, 03/2019)
Day(s) Performed
Monday through Friday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
82570
80349
G0480, if appropriate
Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.