Order Code THCSM Thyroid Function Cascade, Monitor (without Thyroid Peroxidase Antibody), Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1.5 mL

Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.


Useful For

Monitoring patients diagnosed with thyroid disease

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
FRT4C T4 (Thyroxine), Free, S Yes No
T3C T3 (Triiodothyronine), Total, S Yes No

Testing Algorithm

If thyrotropin (TSH) is less than 0.3 mIU/L, then free T4 (FT4, thyroxine) will be performed at an additional charge.

 

If free T4 is normal and the TSH is less than 0.1 mIU/L, then T3 (triiodothyronine) will be performed at an additional charge.

 

If TSH is greater than 4.2 mIU/L, then free T4 will be performed at an additional charge.

Method Name

Electrochemiluminescent Immunoassay (ECLIA)

Reporting Name

Thyroid Cascade (Monitor), S

Specimen Type

Serum

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 7 days
  Frozen  30 days
  Ambient  72 hours

Reject Due To

Gross hemolysis Reject
Gross lipemia OK
Gross icterus OK

Reference Values

0-5 days: 0.7-15.2 mIU/L

6 days-2 months: 0.7-11.0 mIU/L

3-11 months: 0.7-8.4 mIU/L

1-5 years: 0.7-6.0 mIU/L

6-10 years: 0.6-4.8 mIU/L

11-19 years: 0.5-4.3 mIU/L

≥20 years: 0.3-4.2 mIU/L

Method Description

The cobas e immunoassay thyrotropin (TSH) method employs monoclonal antibodies specifically directed against human TSH. A biotinylated monoclonal TSH-specific antibody and a monoclonal TSH-specific antibody labeled with a ruthenium complex react to form a sandwich complex. After the addition of streptavidin-coated microparticles, the complex becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Application of a voltage to the electrode then induces chemiluminescent emission, which is measured by a photomultiplier.(Package insert: Elecsys TSH. Roche Diagnostics; V4.0, 02/2023)

Day(s) Performed

Monday through Sunday

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

84443

84439-(if appropriate)

84480-(if appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
THCSM Thyroid Cascade (Monitor), S 11579-0

 

Result ID Test Result Name Result LOINC Value
STSHM TSH, Sensitive, S 11579-0