Order Code THCSM Thyroid Function Cascade, Monitor (without Thyroid Peroxidase Antibody), Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1.5 mL
Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.
Useful For
Monitoring patients diagnosed with thyroid disease
Reflex Tests
| Test ID | Reporting Name | Available Separately | Always Performed |
|---|---|---|---|
| FRT4C | T4 (Thyroxine), Free, S | Yes | No |
| T3C | T3 (Triiodothyronine), Total, S | Yes | No |
Testing Algorithm
If thyrotropin (TSH) is less than 0.3 mIU/L, then free T4 (FT4, thyroxine) will be performed at an additional charge.
If free T4 is normal and the TSH is less than 0.1 mIU/L, then T3 (triiodothyronine) will be performed at an additional charge.
If TSH is greater than 4.2 mIU/L, then free T4 will be performed at an additional charge.
Method Name
Electrochemiluminescent Immunoassay (ECLIA)
Reporting Name
Thyroid Cascade (Monitor), SSpecimen Type
SerumSpecimen Minimum Volume
1 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 7 days |
| Frozen | 30 days | |
| Ambient | 72 hours |
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | OK |
| Gross icterus | OK |
Reference Values
0-5 days: 0.7-15.2 mIU/L
6 days-2 months: 0.7-11.0 mIU/L
3-11 months: 0.7-8.4 mIU/L
1-5 years: 0.7-6.0 mIU/L
6-10 years: 0.6-4.8 mIU/L
11-19 years: 0.5-4.3 mIU/L
≥20 years: 0.3-4.2 mIU/L
Method Description
The cobas e immunoassay thyrotropin (TSH) method employs monoclonal antibodies specifically directed against human TSH. A biotinylated monoclonal TSH-specific antibody and a monoclonal TSH-specific antibody labeled with a ruthenium complex react to form a sandwich complex. After the addition of streptavidin-coated microparticles, the complex becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Application of a voltage to the electrode then induces chemiluminescent emission, which is measured by a photomultiplier.(Package insert: Elecsys TSH. Roche Diagnostics; V4.0, 02/2023)
Day(s) Performed
Monday through Sunday
Performing Laboratory
Mayo Clinic Laboratories in Rochester
CPT Code Information
84443
84439-(if appropriate)
84480-(if appropriate)
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| THCSM | Thyroid Cascade (Monitor), S | 11579-0 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| STSHM | TSH, Sensitive, S | 11579-0 |