Order Code ZNCU Zinc/Creatinine Ratio, Urine
Specimen Required
Only orderable as part of a profile. For more information see ZNUCR / Zinc/Creatinine Ratio, Random, Urine.
Patient Preparation: High concentrations of barium are known to interfere with most metal tests. If barium-containing contrast media has been administered, the specimen should not be collected for at least 96 hours.
Supplies: Urine Tubes, 10 mL (T068)
Collection Container/Tube: Clean, plastic urine collection container with no metal cap or glued insert
Submission Container/Tube: Plastic urine tube or clean, plastic aliquot container with no metal cap or glued insert
Specimen Volume: 3 mL
Collection Instructions:
1. Collect a random urine specimen.
2. See Metals Analysis Specimen Collection and Transport for complete instructions.
Useful For
Measurement of zinc concentration as a part of identifying the cause of abnormal serum zinc concentrations using a random urine specimen
Method Name
Only orderable as part of a profile. For more information see ZNUCR / Zinc/Creatinine Ratio, Random, Urine.
Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
Reporting Name
Zinc/Creat Ratio, USpecimen Type
UrineSpecimen Minimum Volume
2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
Only orderable as part of a profile. For more information see ZNUCR / Zinc/Creatinine Ratio, Random, Urine.
Not applicable
Method Description
The metal of interest is analyzed by inductively coupled plasma mass spectrometry.(Unpublished Mayo method)
Day(s) Performed
Monday, Thursday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
84630